MicroSilk® - AirMasseur® Bath |
SYMPTOMS |
POSSIBLE CAUSES |
RECOMMENDED ACTION |
Air bath system won’t operate. |
- No power to air bath unit.
- Blower Motor is not plugged in.
- Keypad disconnected.
|
- Reset circuit breakers and check GFCI. Check fuses and replace if bad.
- Make sure plug is fully inserted into the outlet.
- Check and reconnect if necessary.
|
Blower shuts off by itself or before time elapses. |
- Blower motor overheated and thermal protection device deactivated motor (possibly low voltage).
- GFCI tripped.
|
- Check that blower has sufficient ventilation, and that the intake into the blower is not blocked. Clear and allow motor to cool down. (Check service & wire size.)
- Refer to installer/dealer.
|
Circuit breaker trips repeatedly. |
- Defective breaker.
- Short circuit between bath and blower breaker box.
- Other items are connected to the same circuit.
|
- Replace breaker.
- Refer to installer/dealer.
- Refer to installer/dealer.
|
Blower does not shut off. |
- Defective keypad or timer.
|
- Refer to installer/dealer. Replace keypad or control
|
Air bath does not function properly while in the pulse or wave mode (Signature Edition). |
- Blower speed setting is set too low.
|
- Change to a mid-range air speed setting before switching over to Wave or Pulse modes.
|
Standard Edition Purge cycle won’t operate. |
- Purge cycle was disabled.
|
- Remove power to the bath, either by the circuit breaker or by unplugging and replugging the blower from the supply outlet.
|
LED light will not operate |
- Light bulb is loose in socket
|
- Access bulb and assure it is properly installed
|